We offer Danfoss Thermostatic expansion valves which are available as complete valves with a fixed orifice or in parts - with an exchangeable orifice (body + orifice). These valves have been optimized for a variety of refrigerants and operating ranges with fixed or adjustable superheat settings and many connection options. There is a possibility to order valves with special temperature ranges, high-pressure refrigerants (CO2/R744), various diameter sizes, and connection types, including solder, flare, ODF, and ORFS.

[read more]

Parameters

Performance

All

All

All

All

All

All

T 2 / TE 2

T 2 / TE 2

Danfoss
Body geometry:
Angleway
Flow direction:
Single-flow, Bi-flow
Pressure equalization:
Internal, External
MOP point:
None, 0°C, 10°C, 15°C, 20°C
Capillary tube length [mm]:
1500, 5000
TE 2 CO₂

TE 2 CO₂

Danfoss
Body geometry:
Angleway
Flow direction:
Single-flow
Pressure equalization:
External
MOP point:
5°C
Capillary tube length [mm]:
1500
TE 5 - TE 55

TE 5 - TE 55

Danfoss
Body geometry:
Angleway, Straightway
Flow direction:
Single-flow, Bi-flow
Pressure equalization:
External
MOP point:
None, -25°C, -20°C, -10°C, -5°C, 0°C, 15°C
Capillary tube length [mm]:
3000, 5000
TU / TC

TU / TC

Danfoss
Body geometry:
Angleway, Straightway
Flow direction:
Single-flow, Bi-flow
Pressure equalization:
Internal, External
MOP point:
None, -20°C, -10°C, 0°C, 5°C, 10°C, 15°C
Capillary tube length [mm]:
300, 800, 900, 1500
TGE

TGE

Danfoss
Body geometry:
Straightway
Flow direction:
Bi-flow
Pressure equalization:
External
MOP point:
None, 5°C, 10°C, 15°C
Capillary tube length [mm]:
1500, 3000, 4000
TD 1 / TDE 1

TD 1 / TDE 1

Danfoss
Body geometry:
Angleway, Straightway
Flow direction:
Single-flow
Pressure equalization:
Internal, External
MOP point:
None, -5°C, 0°C, 10°C, 15°C, 20°C
Capillary tube length [mm]:
750

We offer Danfoss Thermostatic expansion valves which are available as complete valves with a fixed orifice or in parts -  with an exchangeable orifice (body + orifice). These valves have been optimized for a variety of refrigerants and operating ranges with fixed or adjustable superheat settings and many connection options. There is a possibility to order valves with special temperature ranges, high-pressure refrigerants (CO2/R744), various diameter sizes, and connection types,  including solder, flare, ODF, and ORFS.

Thermostatic expansion valves are used in:

  • Traditional refrigeration systems
  • Heat pump systems
  • Air conditioning systems
  • Liquid chillers
  • Mobile refrigeration units
  • Chillers

The valves control the injection of liquid refrigerant into evaporators and protect the compressor motor against liquid refrigerant. They ensure precise operation and long service life of your refrigeration system. The thermostatic expansion valve allows you to keep a constant superheat (or refrigerant level) at varying load situations in the refrigeration system to save energy. Compact and lightweight design available with  adjustable and non-adjustable superheat setting,  high working pressure and (MOP) Maximum Operating Pressure characterized thermostatic expansion valves. Option with MOP function charge which protects the compressor motor against excessive evaporating pressure during normal operation.

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy