Send feedback
Report an error

The range of refrigeration automation includes Danfoss and GVN hermetic filter driers/dehydrators and mechanical filters designed to protect refrigeration, freezing and air conditioning systems from moisture, acids and solid particles.

By eliminating these particles from the refrigerant, the system is protected against undesirable chemical reactions such as corrosion or ice formation, which may cause the failure of compressor. The range of filter driers/dehydrators includes hermetic filters with a fixed and plug-in cartridge, one-way and two-way filters. They are designed to work with refrigerants from the following groups: HFC, HCHC, HFO, available with a lot of different  connection types and in various sizes.

Parameters

Performance

All

All

All

All

All

All

All

DCR

DCR

Danfoss
Refrigerant:
R134a, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R507, R513A
Flow direction:
Single-flow
Filter core volume [cm³]:
727 - 2,908
Flow acid capacity [g]:
24.85 - 99.40
H48

H48

GVN
Refrigerant:
R22, R134a, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R744 (CO₂), R1234yf, R1234ze
Flow direction:
Single-flow
Filter core volume [cm³]:
800 - 3,200
Flow acid capacity [g]:
23.70 - 94.80
H100

H100

GVN
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R1234yf, R1234ze
Flow direction:
Single-flow
Filter core volume [cm³]:
1,600
DCL

DCL

Danfoss
Refrigerant:
R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454B, R454C, R455A, R507, R513A, R600a, R1234yf
Flow direction:
Single-flow
Filter core volume [cm³]:
13 - 711
Flow acid capacity [g]:
0.33 - 16.98
DCLE

DCLE

Danfoss
Refrigerant:
R290, R32, R452B, R454A, R454B, R454C, R455A, R600a, R1234yf
Flow direction:
Single-flow
Filter core volume [cm³]:
21 - 59
Flow acid capacity [g]:
0.53 - 0.85
DML

DML

Danfoss
Refrigerant:
R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454B, R454C, R455A, R507, R513A, R600a, R1234yf
Flow direction:
Single-flow
Filter core volume [cm³]:
13 - 711
Flow acid capacity [g]:
0.13 - 6.55
DMLE

DMLE

Danfoss
Refrigerant:
R290, R32, R452B, R454A, R454B, R454C, R455A, R600a, R1234yf
Flow direction:
Single-flow
Filter core volume [cm³]:
13 - 59
Flow acid capacity [g]:
0.13 - 0.54
DAS

DAS

Danfoss
Refrigerant:
R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454B, R454C, R455A, R507, R513A, R600a, R1234yf
Flow direction:
Single-flow
Filter core volume [cm³]:
59 - 517
Flow acid capacity [g]:
3.79 - 34.57
DCB

DCB

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R450A, R452A, R452B, R454A, R454B, R600a, R1234yf
Flow direction:
Bi-flow
Filter core volume [cm³]:
44 - 204
Flow acid capacity [g]:
0.99 - 4.51
DMB

DMB

Danfoss
Refrigerant:
R22, R134a, R32, R404A, R407C, R410A, R448A, R449A, R450A, R454A, R454C, R455A, R513A, R600a, R1234yf
Flow direction:
Bi-flow
Filter core volume [cm³]:
44 - 204
Flow acid capacity [g]:
0.38 - 1.77
DMT

DMT

Danfoss
Refrigerant:
R744 (CO₂)
Flow direction:
Single-flow
Filter core volume [cm³]:
59 - 93
Flow acid capacity [g]:
0.54 - 6.44
DCC

DCC

Danfoss
Refrigerant:
R22, R134a, R290, R32, R407C, R407F, R410A, R600a, R717 (ammonia)
Flow direction:
Single-flow
Filter core volume [cm³]:
30
Flow acid capacity [g]:
0.68
Filter tank:
Yes
DMC

DMC

Danfoss
Refrigerant:
R22, R134a, R290, R32, R407C, R407F, R410A, R600a
Flow direction:
Single-flow
Filter core volume [cm³]:
30 - 128
Flow acid capacity [g]:
0.27 - 1.20
Filter tank:
Yes
GMH

GMH

GVN
Refrigerant:
R22, R134a, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R515B, R1234yf, R1234ze
Flow direction:
Single-flow
Filter core volume [cm³]:
93 - 1,232
GCH

GCH

GVN
Refrigerant:
R22, R134a, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R515B, R1234yf, R1234ze
Flow direction:
Single-flow
Filter core volume [cm³]:
93 - 1,232

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy