Send feedback
Report an error

The range of Danfoss control valves incudes: evaporating pressure regulators, suction pressure regulators, liquid tank pressure regulators, liquid tank pressure regulators, hot gas regulators and manual regulating valves. Valves are available  in a wide range of performance and operation, they are adapted to work with refrigerants from the HCFC, HFC and HC groups. The adjustment range is from 0 to 20 bar, depends on series. Models in accordance with ATEX zone 2 are available.

[read more]

Parameters

All

All

All

All

TUH

TUH

Danfoss
Application:
Performance regulator
Refrigerant:
R22, R134a, R404A, R407C, R410A, R513A
Inlet connection type:
Soldered
Maximum working pressure [bar]:
34 - 46
TGHE

TGHE

Danfoss
Application:
Performance regulator
Refrigerant:
R134a, R410A
Inlet connection type:
Soldered
Maximum working pressure [bar]:
49
REG

REG

Danfoss
Application:
Manual control valve
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R513A, R515B, R600a, R717 (ammonia), R744 (CO₂), R1234yf
Inlet connection type:
Welded, Thread
Maximum working pressure [bar]:
52
KVP

KVP

Danfoss
Application:
Evaporating pressure regulator
Refrigerant:
R22, R134a, R290, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454A, R454C, R455A, R513A, R515B, R600a, R1234yf
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
18
KVL

KVL

Danfoss
Application:
Suction pressure regulator
Refrigerant:
R22, R134a, R290, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454A, R454C, R455A, R513A, R515B, R600a, R1234yf
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
18
KVC

KVC

Danfoss
Application:
Hot gas bleed regulator
Refrigerant:
R22, R134a, R290, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454A, R454C, R455A, R513A, R515B, R600a, R1234yf
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
28
KVD

KVD

Danfoss
Application:
Liquid tank pressure regulator
Refrigerant:
R22, R134a, R290, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454A, R454C, R455A, R513A, R515B, R600a, R1234yf
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
28
CPCE

CPCE

Danfoss
Application:
Pressure regulator
Refrigerant:
R22, R134a, R290, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R454A, R454C, R455A, R513A, R515B, R600a
Inlet connection type:
Flare, Soldered
Maximum working pressure [bar]:
28

The range of Danfoss control valves incudes: evaporating pressure regulators, suction pressure regulators, liquid tank pressure regulators, liquid tank pressure regulators, hot gas regulators and manual regulating valves. Valves are available  in a wide range of performance and operation, they are adapted to work with refrigerants from the HCFC, HFC and HC groups. The adjustment range is from 0 to 20 bar, depends on series. Models in accordance with ATEX zone 2 are available.

The Danfoss control valves applications:

  • Traditional refrigeration systems
  • Air- conditioning devices
  • Cold rooms
  • Refrigerated showcases
  • Air dryers
  • Mobile refrigeration systems

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika SA. Please read the full Terms of Use.

Sales of equipment

We are a direct importer, representative and authorized distributor of the world's leading refrigeration and air conditioning manufacturers. The main activity of the company is wholesale and distribution of HVACR equipment and accessories, including heat pumps and chillers, through its own network of branches.

Check our offer

Technical support

We actively support our HVACR Installers and Designers. We organize product trainings; provide assistance and technical advice to refrigeration and air conditioning engineers at every stage of the investment realization. Hundreds of successful investments confirm our competence and extensive experience.

Check our offer

Investment processes

Our organizational structures include Investment Implementation Departments, which, based on the skills of engineers and designers, in cooperation with installation companies from the investment area, are able to design and implement the most modern cooling, freezing and air conditioning units.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy